• Sanitizer – Class leading range of products for problem water supplies with normal pH values
  • Removes hardness and high levels of iron and manganese (up to 15 ppm combined) in a single pass
  • Integrated high output chlorine generator sanitizes media bed during regeneration, eliminating iron bacteria
  • “HS” models will treat up to 0.5 ppm of sulphur/hydrogen sulphide (“rotten eggs”)
  • Advanced, programmable control valve for backwash and regeneration sequences
VIQUA
Part Number: AWP1465SE2
Product ID: AWP1465SE2
AWP1465SE2

AWP1465SE2

Class Leading Hardness Sanitizer

Part Number: AWP1465SE2
Ideal For: Hardness, Iron and/or Manganese, Smell

Product Details

  • Sanitizer – Class leading range of products for problem water supplies with normal pH values
  • Removes hardness and high levels of iron and manganese (up to 15 ppm combined) in a single pass
  • Integrated high output chlorine generator sanitizes media bed during regeneration, eliminating iron bacteria
  • “HS” models will treat up to 0.5 ppm of sulphur/hydrogen sulphide (“rotten eggs”)
  • Advanced, programmable control valve for backwash and regeneration sequences

Features & Specs

FLOW RATES    
  Peak Flow (15 psi pressure drop) 19.0 GPM
  Continuous Flow (5 psi pressure drop) 10.0 GPM
  Backwash Flow rate 7.5 GPM
 SPECIFICATIONS    
  Grains Capacity/lbs of Salt (Maximum) 84,000/37
  Grains Capacity/lbs of Salt (Medium) 68,000/22
  Grains Capacity/lbs of Salt (Minimum) 40,000/13
  Volume of Media (cu.ft.) 3.00
  Max Hardness (grains per gallon) 80
  Max Iron (ppm/mg/L) 15
  Min pH 7.0
  Water use per regeneration (gallons) 205
  Overall Dimensions 32″ x 73″ (81 cm x 185 cm)
  Connection Size 1″ Brass Sweat
  Temperature Range 1-38˚C (33-100˚F)
  Pressure Range 25-100 psi