S2Q-DWS

The quality of drinking water can change with time and become contaminated with harmful bacteria. The SterilightTM drinking water system is a reliable, economical and chemical-free way to safeguard drinking water in any residential application. The Sterilight drinking water system has been designed and tested to ensure quality drinking water is at everyone’s finger tips.

Features of the Sterilight UV purification drinking water system
  • Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli and viruses not visible to the naked eye.
  • Specially designed and tested Sterilume™-EX 254 nm lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification.
  • The system is easy to maintain and service with easy lamp and cartridge replacement and quick disconnect fittings.
  • Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
  • The Silver "basic" power supply visually displays the remaining lamp life and will go into alarm if the lamp fails to notify the homeowner.
  • Comes equipped with a 5-micron sediment pre-filter to reduce particles in the water.
  • Also comes equipped with a 5-micron carbon filter to reduce taste and odour of chlorine.
  • Complete do-it-yourself kit including faucet, saddle valve, tubing, and fittings available with the this model only.

Specifications

View Specs
Manuals
Brochures

Accessories

Currently Unavailable

There are no accessories available for this product at the current time.

Replacement Parts

AWP110

AWP117

Sterilume EX UV Lamps

S2Q & SC4 series, 3-4 gpm [33 cm (13")] (fits S2Q-PA, S2Q-PA/2, SSM-17, SSM-17/2, S2Q, S2Q/2, S2Q-GOLD, S2Q-GOLD/2, SC4, SC4/2)

Quartz Sleeve

S2Q-PA, SSM-17, S2Q & S2Q-GOLD series [2 x 2.3 x 37.5 cm (0.8" x 0.9" x 14.8"), open]

O-ring

o-ring for RN-001 ( replaces OR-212)

Power Supply

SilverÔäó controller for all "BASIC" models, water-tight case, 4 segment LED display showing lamp life remaining and total operating time, audible indicator, one controller operates 100-240V./50-60Hz. (c/w lamp connector) (detachable IEC power cord sold separately) Note: this repl ...

Product Flow Rates

Dosage
UV
Rate
16 mJ/cm² 95% UVT @ eoll 15 gpm
30 mJ/cm² 95% UVT @ eoll 11 gpm
40 mJ/cm² 95% UVT @ eoll 7.5 gpm

Product Specificiations

Dimensions
Width 15.5 inches
Height 16 inches
Diameter 6 inches
Inlet/Outlet Port Size 1/2" MNPT
Shipping Weight 7.3 kg
Reactor Chamber Material 304 S.S.
Electrical
Max. current 1.5 Amp
Lamp Type Sterilume™-EX
(standard-output)
Power Consumption 22 W
Lamp Power 17 W
Voltage 100-250V / 50-60Hz
Operating Parameters
Maximum humidity 95%
Maximum hardness 120 ppm
(7 grains per gallon)
Maximum iron 0.3 ppm
Ambient Temperature 2-40 °C
(36-104 °F)
Maximum Operating Pressure 125 PSI
(8.62 bar)
Minimum Operating Pressure 4 PSI
(27.5 kPa)
Minimum UVT 75 %
Installation Orientation Vertical
Features
UV Intensity Monitor No
Visual "Power On" Yes
Audible Lamp Failure Yes
Audible alarm mute button Yes
Visual Lamp Life Remaining Yes
Lamp Replacement Indicator Yes
Diagnostic Check No
Safety Interlock No
Flow Restrictor No
COMMcenter control package No
CoolTouch fan No
Colour-coded plug and play connections No
Safety cap & special lamp plug Yes
Reference card No
Solenoid operation indicator No
Flow Pacing No
Solenoid Valve No
4-20 Interface No
Dry Contact No
Certifications
CSA Yes
CE Yes
Filters
Sediment Filtration Yes, 5 micron
Filter Housing Two 10" Slimline
Carbon Filtration Yes, 5 micron